What sensors are compatible with the Hawk?

Written by Cameron Everett

Updated at September 17th, 2024

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Contact Support
  • Home
  • Devices
  • Cellular
  • Data Loggers
  • Hawk IoT Datalogger
  • Getting Started

Table of Contents

Sensor Interfaces that generally do not require Custom FW Sensor Interfaces that will require Custom FW

The Hawk can integrate with essentially “any” sensor.

If a sensor isn't compatible with one of our cards, we can develop one for you (please contact DM Support).

The Hawk offers numerous different inputs including:

  • Digital Inputs
  • Analog (0-30V) inputs
  • 4-20mA
  • Bluetooth®
  • I2C
  • 1-wire
  • SDI-12
  • RS232
  • RS485

Some of these sensor interfaces require custom FW integration, some do not.

Sensor Interfaces that generally do not require Custom FW

Digital Inputs

Digital Inputs can be used for numerous applications on the Hawk.

Doesn't require integration.

Input range: 0-40 DC.

  • Pulse Counting
  • Actions on Digital Input Change

Hawk Baseboard

1 x Digital Input

Agtech1

1 x Digital Input 

(IO7)

RS1 Card

1 x Digital Input 

(IO7)

Serial Card

2 x Digital Input 

(IO3 and IO4)

Bluetooth+ Card

1 x Digital Input 

(IO4)

Digital Card

5 x Digital Input

(IO5, IO6, IO7, IO8, IO9)

 
 

Analog Inputs

Analog inputs are on a variety of our Hawk cards.

Doesn't require integration.

Input Range: 0-30V Input Range.

  • Configure Analog Input Readings

Agtech2

4 x Analog Inputs 

(IO5, IO6, IO7, IO8)

RS1 Card

1 x Analog Input 

(IO1)

Serial Card

1 x Analog Input 

(IO2)

Bluetooth+ Card

1 x Analog Input 

(IO2)

Digital Card

2 x Analog Inputs

(IO3, IO4)

 
 

4-20mA

Doesn't require integration.

Some cards have direct 4-20mA inputs.

  • Configure 4-20mA Sensor readings on the Hawk

Otherwise, you can configure 4-20mA readings to be read with an additional resistor wired in.

  • Measure a 4-20mA signal with an analog input

Agtech1

1 x 4-20mA Input

(IO9)

RS1 Card

1 x 4-20mA Input

(IO9)

Bluetooth+ Card

1 x 4-20mA Input

(IO1)

 
 

RS485

Currently, RS485 is only available on the RS1 card.

We have created a “Generic” Modbus action which should be able to cater to most use cases.

For more information on that, please see:

  • Generic Modbus RS485 Action
  • Example Generic Modbus RS485 Integration

For help with this configuration, please contact DM Support.

We can also perform a custom integration for specific sensors if required.

For example, please see Custom GA Weather Station Integration

 
 

SDI-12

Most SDI-12 tags that follow the spec should work.

However, not just any SDI-12 commands can be used with our devices.

Please see:

  • Configure SDI-12 Readings
  • SDI-12 Samples
  • Soil Moisture and Temp Probe Application Example

Agtech1

1 x SDI-12 Input

(IO1)

Agtech2

1 x SDI-12 Input

(IO2)

 
 

Bluetooth

The Bluetooth+ Card is the only Hawk card that supports Bluetooth

  • Bluetooth Getting Started Guide
  • Bluetooth Supported Sensors
 
 

Sensor Interfaces that will require Custom FW

I2C

There are a couple of cards that can interface with I2C sensors.

This interface requires integration.

For a list of I2C sensors that we have integrated with the Hawk, please see the articles in this folder: I2C

  • Configure I2C sensor readings.

Agtech1

I2C SDA

(IO4)

I2C SCL

(IO6)

Bluetooth+ Card

I2C SDA

(IO6)

I2C SCL

(IO5)

 
 

1-wire

Typically these sensors require integration.

For a list of 1-wire sensors that we have integrated with the Hawk, please see the articles in this folder: 1-Wire

Agtech1

1 x 1-wire input

(IO8)

Agtech2

1 x 1-wire input

(IO4)

RS1

1 x 1-wire input

(IO8)

 
 

RS232

Sensors that use RS232 require custom firmware to work with the Hawk.

RS232 is only available on the Serial Card.

If you want to use an RS232 sensor with the Hawk please contact Digital Matter support.

 
 

TTL

Sensors that use TTL require custom firmware to work with the Hawk.

TTL is only available on the Serial Card.

If you want to use an TTL sensor with the Hawk please contact Digital Matter support.

 
 
sensor assistance hawk monitoring sensor supported

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Hawk Introduction and Concepts
  • Hawk Baseboard and IO Card Details
  • Hawk Upload Settings
  • Hawk Dimensions

Subscribe to Partner News

Subscribe to our mailing list to receive Digital Matter news, product and tehnical updates, and more.

Subscribe

Copyright © Digital Matter . All Rights Reserved.

Privacy Contact Support

Knowledge Base Software powered by Helpjuice

Expand