[HAWK] - Configure SDI-12 Readings

Written by Matthew Clark-Massera

Updated at January 14th, 2025

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Contact Support
  • Home
  • Devices
  • Cellular
  • Data Loggers
  • Hawk IoT Datalogger
  • SDI-12

Table of Contents

What SDI-12 Commands does the Hawk Use? C! and M! Configure SDI-12 Readings Configure Task Configure Vboost Voltage Level Configure SDI-Reading FID = 4: SDI-12 Device Identification FID = 5: SDI-12 Measurement FID = 34: SDI-12 Measurement 2 Common SDI-12 Errors 0x1 - Boot Error 0x2 - Read Error

The SDI-12 interface is a low data rate protocol designed for agricultural and scientific sensors (SDI-12 Website).

A soil moisture probe will often have multiple sensors along its length. Each sensor can have an address between 0 and 9 (inclusive), and allows for up to 10 different 'measurements'. Each of these measurements can actually return a number of different values (up to 15). For example, a soil moisture probe may have a soil moisture and soil temperature measurements, and each of these will return a number of values, each being taken at a certain point along the probe.

All Hawk IO Cards with SDI-12 capabilities are programmed to automatically interface with Measurement (M!) commands from SDI-12 sensors. In addition, from FW v 1.14, the Agtech1 card can also use C! commands.

See "Configure SDI-12 Readings" below for more information. If you need to read alternate measurements from SDI-12 sensors such as Verification commands (V!) please contact Digital Matter support.

What SDI-12 Commands does the Hawk Use?

C! and M!

The Hawk mainly uses the M! command. It is mainly designed around the use-case of monitoring soil moisture probes. Implementing multiple arbitrary commands in a specific sequence generically is more complicated - but contact us if you have specific requirements to discuss the options.
The full control flow of the SDI-12 measurement, for an address a, and measurement type t, is: 

Tx: aI! (identify device)
Rx: axxxxx…. The response gets sent as part of the SDI12 data. If no response, then we give up this measurement.

For each measurement parameter, the following goes through each set bit in the mask

Tx: aM! (or aMt! if the type is not 0)
Rx: aXXXn. XXX is how long we need to wait before the samples are ready, and n is how many it will return (both can be 0).

After waiting XXX seconds, the following goes through each value of n, from 0 to 9, until either 0 data is returned (but still a response), or we reach 15 individual values returned. Each aDn command can return more than one value
Tx: aDn
Rx: a<data>
If at any time no response is heard, the measurement is aborted.

Configure SDI-12 Readings

Configure Task

Configure SDI-12 Action 1 or 2 as an action for a task. The below task is for an SDI-12 reading logged + uploaded hourly.

Configure Vboost Voltage Level

While the SDI-12 bus operates at 5V, most SDI-12 probes require 12V to power the sensors. 

We need to tell the Hawk to output 12V via the IO Card Vboost output.

Configure SDI-Reading

We specify

SDI 12 Address

Address of the probe to read - find in the data sheet of the sensor. 

Log Identification/Use Old Data Field

SDI-12 data is sent in the following fields. Field 34 is new to the Hawk. 

If we only have 1 SDI-12 measurement we are taking, from 1 address, it is not necessary to identify this in the payload. So to save data we can select Log Identification as No. 

In general the default Log Identification = No and Use old Data Field = No should be used for most applications.

FID = 4: SDI-12 Device Identification

Length = N + 1

Offset

Data Type

Length

Description

Unit

0

BYTE

1

Device Address

(SDI12 single char address)

 

1

BYTE

N

SDI12 Identification string

(typically 30 ASCII characters)

 

FID = 5: SDI-12 Measurement

Length = 1 + N*4

The SDI12 spec allows for a device to support 10 different types of measurements (0-9).

Offset

Data Type

Length

Description

Unit

0

BYTE

1

SDI12 Measurement Type (0-9)

 

1 + N*4

INT32

4

Measurement (scaled by 1000)

<n data values follow>

Scaled by 1000

Eg milli-degrees centigrade

FID = 34: SDI-12 Measurement 2

Length =3 + N * X

This field replaces FID 4 on newer devices.

The SDI12 spec allows for a device to support 10 different types of measurements (0-9).

Offset

Data Type

Length

Description

Unit

0

BYTE

1

Device Address

(SDI12 single char address)

 

1

BYTE

1

SDI12 Measurement Type (0-9)

 

2

BYTE

1

SDI12 Data Format

0x00 = Scaled by 1000, stored in INT32

 

Other values are reserved.

3

Dependant on format

N * X

N measurements of size X, specified by the format.

 

Log Identification

Use Old Data Field

Fields Sent

No

No

FID 34

No

Yes

FID 5

Yes

No

FID 4 + FID 34

Yes

Yes

FID 4 + FID 5

Command Type (C or M)

Defines which command to send to the sensor.

C! commands are only available on Agtech1 FW v1.14+ as of Septemeber 2024.

Plan is to port this functionality to the Agtech2 and Bluetooth Card moving forward.

Please review the Hawk Firmware Release Notes for the appropriate card to see if the functionality is in place.

Power on Delay

Most sensors require some time after power is applied to 'warm-up' or settle down before the reading is taken.

Run Measurement N

Select from the dropdowns which measurements we would like to run

Example

  • Sensor Address 0
  • Use the new data field, with no ID field
  • Power on delay 15 seconds
  • Measurements 1, 4 and 7

A screenshot of a computer

Description automatically generated with low confidence

Common SDI-12 Errors

0x1 - Boot Error

We can get the boot error if there is an issue getting the sensor ID. This could be due to using the wrong address, or a connection issue.
 

0x2 - Read Error

This is an issue getting the measurement/reading. It is difficult to say exactly what the issue is.
If it is not the wiring, it could be an issue with the sensor or some timing issue in the integration.
Please thoroughly test multiple sensors with multiple Hawks, and contact support if needed.

configure sdi-12 hawk

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

Subscribe to Partner News

Subscribe to our mailing list to receive Digital Matter news, product and tehnical updates, and more.

Subscribe

Copyright © Digital Matter . All Rights Reserved.

Privacy Contact Support

Knowledge Base Software powered by Helpjuice

Expand