Default Tracking Parameters [G120]
Below is how a G120 operates out of the box
- Stationary - Hourly Heartbeats
- The device will log a heartbeat record, connect to the server and refresh its GPS data every 60 minutes.
- Trip Tracking - Wired and Emulated ignition - The G120 will start a trip if either the
- Ignition wire is pulled high, i.e, over 5v is applied to the ignition wire, or
- Movement is detected >150m of movement from the initial position is required to start a trip.
- Logging - When the device is in trip, it will turn on it's GPS module and cellular modem and log records based on:
- Time interval
- log a record every 60 seconds or;
- Distance interval
- when 500m is travelled or;
- Heading Change
- when direction is changed by 10° over a long distance (>150m)
- heading change over short distance can also be configured, but this is disabled by default
- Time interval