The Hawk's operation centres around the concept of a "Task" - which is a selection of actions, performed on a schedule. Up to two tasks can be configured, with up to three actions each. 

Broadly, we can think of the tasks as the time interval, and the actions of the sensor readings we take. 

If we don't configure a task, the Hawk by default will do nothing but heartbeat once daily. 

We may also need to configure our sensors separately, on other parameter tabs to ensure the setup is correct for when the task runs. 

There are two tasks as there may be some sensors we wish to sample frequently, and others less frequently. E.g. sample temp every 10 min, tank level every 2hrs.

Task Parameters

Period Unit + Schedule Period
Set how often the task (and actions) occur
Upload Multiplier
Upload every N tasks
GPS Multiplier
If the asset is stationary, or moves infrequently, we might disable GPS completely (set to 0) - or set the multiplier to a large number so fixes occur less often. This conserves energy and extends battery life
Start/End Period
We might only want to run the task during a certain time (i.e. during day). Or we might want it to run every 10 min during 6am -> 6pm, and hourly outside that - in which case we can set up 2 tasks to achieve this.
Action
Actions are typically which sensor readings we want to take - but these include:


Example Task Configurations

Some examples are given below. These serve to illustrate how to configure tasks, generally we need to configure additional parameters specific to the sensor type and individual sensor.

Read and report temp/hum every 10 minutes
  1. Run the task (take a sensor reading) every 10 min
  2. Upload every single task - so we sample and upload every 10 min
  3. Run I2C Action 1

We configure I2C action 1 to sample the sensor type we have connected - DM Ambient (Temp/Hum) Sensor

Sample 4-20mA tank level sensor every 10 min, uploading hourly, disable GPS
  1. Read value every 10 min
  2. We upload every 6 tasks - so every 6 x 10 min = hourly
  3. GPS Multiplier = 0 to disable GPS - the Hawk is mounted in a stationary location so we don't care about GPS position
  4. Sample the 4-20mA sensor

For the 4-20mA sensor, we configure a power on delay and which analogue the value should be placed in the Hawk's payload.

Read Temperature every 5 min, Soil Moisture Probe hourly
Task 1 the Temp reading every 5 min. 

We set the upload multiplier to 0 to not upload due to this task - the readings will be logged and uploaded together with the task 2 upload.


Task 2 the soil moisture reading (via SDI-12 probe) hourly, and upload.

Sample every 15 min during day, every 6hrs at night
To save power we may only require aggressive monitoring during working hours.

1. Set timezone

2. Run task 1 (15 min sample + upload from 0600 → 1800

3. Run task 2 (6 hour sample + upload) from 1800 → 0600

Task Detail

It may be useful to know how the Hawk processes tasks. When a task runs, the following occurs:

  1. Start Task 
  2. GPS started if requested 
  3. Action 1 
  4. Action 2 
  5. Action 3 
  6. Action 4 
  7. Wait for GPS to finish 
  8. Pack readings + results up into record and log
  9. Check Analog thresholds 
  10. Upload if necessary