Table of Contents

Hawk Lite Panel Requirements Connections Charging Internal Battery Charging in Extreme Temperatures Monitoring Panel Output/Hawk Charging Vext Digital Input

The Hawk Pro can be fitted with a 3500mAh LiPo rechargeable battery.

Hawk Lite

The Hawk Lite does not have an internal rechargeable battery and therefore is NOT compatible with external solar power.

 

For permanent installations, aggressive sampling/upload rates, or when using power-hungry sensors - a solar panel can be connected to the Hawk Pro. 

DO NOT CONNECT THE HAWK TO A SOLAR PANEL AND AN EXTERNAL BATTERY SIMULTANEOUSLY THROUGH THE SAME EXTERNAL VOLTAGE INPUT.

Without proper protective circuitry in place to protect the external battery and the solar panel, current WILL flow in the wrong direction and could cause a fire or damage to components. 

 

Panel Requirements

As of the November 2023 build, Hawk Pro PCBs come with a switch to allow customers to select between ‘low’ (85mA) and ‘high’  (400mA) charge rates. When customers may receive their first devices of this type is dependent on demand and available stock on hand.

Devices with serial numbers greater than 886406 will have this switch.

Setting the switch to “Off” will set the charge rate to “Low”. Keeping the switch “On” will keep the charge rate “High”.

By default, all boards will have the charge rate set to “High”. Only turn this switch "Off" if you want to connect the Hawk to a small (~1W) solar panel.

 

Low Charge Rate 

High Charge Rate

Charge Rate

85mA

400mA

Minimum Panel Size

1W+

5W+

Switch Configuration

“Off”

Default ("On")

All panels must provide 6V+ (Hawk min operating voltage).

For continuous operation at high temperatures and high output load currents, we recommend an input voltage of 12V or higher.  

Connections

Connect the panel to the external power terminals on the Hawk base-board (Vin + GND)

Charging Internal Battery

In order to charge the internal battery, the input voltage must be switched to 5V to work correctly with the charging circuit.

Path:

  • V_in -> switcher -> 5V ->charger
  • The switcher is ~90% efficient when converting an input voltage to 5V.
  • The Hawk internal battery is charged at a maximum current of 400mA.
  • Therefore, 400mA at 5V = 2W.
  • Accounting for ~10% conversion loss, the power required is ~2.2W.
  • Therefore, a 5W panel is recommended to ensure 2.2W can be met even when the panel isn't in strong sunlight.

The internal battery is charged at a maximum current of 400mA. This means it will take 8hrs 45 min to fully charge the battery from empty. 

Charging in Extreme Temperatures

It is important to note that the backup battery will not be charged if the temperature is <-10°C, or >45°C. This means that if the device is left exposed to the sun on a hot day, a solar panel will not charge the battery. 
Ensure you take measures to reduce the internal temperature of the unit as much as possible (i.e. mount the device under the panel in the shade).

Monitoring Panel Output/Hawk Charging

  • The Voltage output by the panel will simply be the input to the Hawk, which is reported in Analogue 2.
  • The battery is fully charged at ~4.1V.
  • The battery is empty at approximately 3.6-3.7V.

Vext Digital Input

The Vext Parameter tab can be configured to map the external power status (Good/Not Good) to Digital Input 3.

A screenshot of a computer program

Description automatically generated with medium confidence

In general, it is best to leave this on defaults (no active or inactive action) - since a solar panel voltage may fluctuate during the day leading to a large number of unnecessary logs. 

This is more typically used when connected to mains power and we desire an instant alert on the server when this is disconnected.

hawk solar panel

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Encoding the Yabby 3 LoRaWAN® Downlink
  • Yabby 3 LoRaWAN® Battery Life Estimate Calculator
  • Yabby 3 LoRaWAN® Firmware Release Notes

Subscribe to Partner News

Subscribe to our mailing list to receive Digital Matter news, product and tehnical updates, and more.

Subscribe

Copyright © Digital Matter . All Rights Reserved.

Privacy Contact Support

Knowledge Base Software powered by Helpjuice

Expand