Hawk - Connecting GA Weather Station

Written by Matthew Clark-Massera

Updated at May 22nd, 2024

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Contact Support
  • Home
  • Devices
  • Cellular
  • Data Loggers
  • Hawk IoT Datalogger
  • RS-485

Table of Contents

Related Articles 3rd Party Sensor IO Card Wiring Parameters RS485 Action Parameters Warning! Task Parameters Output/Conversion

Related Articles

Please ensure to also read the below for full details on configuring Tasks for the Hawk

  • Hawk Operation - Task Schedules
 

3rd Party Sensor

The GA Weather Station is a 3rd Party sensor - the advice given below is general. Specific guidance on installation and usage should be obtained directly from the manufacturer. The instructions below are based on a sensor tested at the time of article writing - things may change.

 

The GA Weather Station is a Hongyuv HY-WDC6E Weather Station. 

IO Card

Ensure a plug-in IO card with an RS-485 interface is fitted to the Hawk. Currently, the only card with this interface is the RS-1 card.

Wiring

GA Station Connect to
Red (V+)  7-30V DC Power (Separate to Hawk)
The Station cannot be powered via the Hawk due to it's high current requirement and need to remain permanently powered
Black (GND)
 
GND
Yellow (RS485 A) Hawk IO 4 (RS485 A)
 
Green (RS485 B) Hawk IO 3 (RS485 B)

Parameters

RS485 Action Parameters

  1. Select GA Station as the Sensor Type
  2. Choose an Analogue Offset.
    1. 7 separate readings are reported by the weather station.
       
    2. The offset defines where the first reading goes, with the others in following analogues
    3. In the example below this would be readings in analogues 12,13,14,15,16,17 and 18.

Warning!

In order accurately measure accumalated rainfall, you need to constantly power the weather station.

If the station resets (due to power loss), it will lose its rainfall count.

 

Task Parameters

Ensure the RS485 action you have configured above is set as an action of the task.

Output/Conversion

With the above parameters, the output would be:

Value Type Analogue Units Conversion Example
Temperature INT32 Analogue Offset Value °C * 100 800 = 8°C
Humidity UINT16 Analogue Offset Value + 1 % * 100 5000 = 50%
Wind Speed UINT32 Analogue Offset Value + 2 cm/s 500 = 500cm/s = 18km/h
Wind Direction UINT16 Analogue Offset Value + 3 Degrees 127 = 127°
Pressure UINT32 Analogue Offset Value + 4 Pa 10021 = 10021 Pa = 100.21hPa
Precipitation UINT32 Analogue Offset Value + 5 mm 120 = 120mm
Illuminance UINT32 Analogue Offset Value + 6 mW/mm² 1000 = 1000mW/mm²
weather station hawk

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Generic Modbus RS485 Action
  • Generic Modbus Action Example - Misol Weather Station Configuration