Configuration Setting Initial Values using ASYNC Message What if my device resets?

Applies to:

Device Firmware Version
G70-4G  v1.17+

The G70-4G the capability to accumulate run hours and odometer readings on-board based on the Ignition input (see On Device Odometer and Run Hours).

Also, it can accumulate run hours onboard based on any Digital Input. This is useful to understand the usage of peripherals such as pumps.

Many platforms calculate this server-side based on device data (including Telematics Guru - Setting up Secondary Run Hours), so it is not always necessary to configure this feature in order to track run hours.

However, you can use this feature if your platform can not process the raw values server-side.

The On Device Run Hours feature is configured using the “Odometer" Advanced System Parameter tab and sends data in Field 27 of the integration payload. 

This On-Board Run Hours for Digital inputs feature is configured using the “Run hour” Advanced System Parameter tab. The device sends data in the Analogue Data Fields (6 for INT16 and 7 for INT32) of the integration payload. This is great as most platforms can easily ingest data sent in Analogue Data Fields.

Configuration

Add the Run hour Tab and configure the desired behaviour. 

Parameter Function
Run Time X Digital Input To select which Digital Input we want to monitor
Run Time X Analogue Input The accumulated Run hour data for the selected Digital Input will be sent in this Analogue Input field.
Run Time X Active Level To select which active level of the Digital Input we want to monitor

Setting Initial Values using ASYNC Message

The device's run hour readings can be set via an asynchronous message sent from the server.

See Set Digital Inputs Run time via API call - 0x106 

What if my device resets?

The run hour values are stored in non-volatile memory. This means that even if the device loses power or otherwise resets, they are preserved. The values won't become inaccurate if the device ever resets.

onboard input hours

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Hard Wired Devices: Idle Monitoring
  • Run Hour Monitoring - Battery Powered Devices

Subscribe to Partner News

Subscribe to our mailing list to receive Digital Matter news, product and tehnical updates, and more.

Subscribe

Copyright © Digital Matter . All Rights Reserved.

Privacy Contact Support

Knowledge Base Software powered by Helpjuice

Expand