Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Digital Matter Site
  • Contact Us

Hawk - Configure WNK8010TT Pressure Sensor

Written by Matthew Clark-Massera

Updated at October 6th, 2023

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Contact Support
  • Home
  • Devices
  • Cellular
  • Data Loggers
  • Hawk IoT Datalogger
  • I²C

Table of Contents

Related Articles 3rd Party Sensor IO Card Wiring Firmware Parameters I²C Action Parameters Min/Max Range Task Parameters Output/Conversion

Related Articles

Please ensure to also read the below for full details on configuring Tasks and I²C Sensors for the Hawk

  • Hawk Operation - Task Schedules
  • Configure I²C Sensor Readings
 

The WNK8010-TT sensor is a pressure sensor commonly used for tank level measurements. 

The WNK8010-TT has been integrated and tested specifcially - but other sensors of this family should also work.

3rd Party Sensor

As this is a 3rd Party sensor - the advice given below is general. Always check the product datasheet direct from the manufacturer. Specific guidance on installation and usage should be obtained directly from the manufacturer. The instructions below are based on a sensor tested at the time of article writing - things may change.

 

IO Card

Ensure a plug-in IO card with an I²C interface is fitted to the Hawk. Currently the only card with this interface is the AgTech1 card.

Wiring

NB - confusingly, this sensor uses blue for Ground and not black. 

WNK8010TT Agtech1 Bluetooth+
VCC (Red) Hawk IO 5 Hawk IO 7
SCL (Yellow)
 
Hawk IO 6 Hawk IO 5
SDA (Black) Hawk IO 4 Hawk IO 6
GND (Blue) Hawk GND Hawk GND

Firmware

The AgTech1 card firmware should be set to 1.5.

IO card firmware can be set from the Device Details page of the Hawk which the card is plugged into. 

Parameters

I²C Action Parameters

  1. Select WNK Pressure Sensor as the Sensor Type
  2. Choose an Analogue to write the values to. 2 Values are returned, Pressure and Temperature.
  3. Sensor Parameter 1 is the pressure range minimum (in cm)
  4. Sensor Parameter 2 is the pressure range maximum (in cm) 

The I²C address can be left blank. It is fixed at 0x6D

Min/Max Range

The sensors come in various sizes and ranges - i.e 0-2000 or 0-4000. This is what the min/max values are used for. 

I.e if you are using the 0-4000 version, enter 0 for the min and 4000 for the max. 

The units of the sensor can be found on the sensor datasheet - mmH2O. 

Task Parameters

Ensure the I²C action you have configured above (Action 1 or 2) is set as an action of the task.

Output/Conversion

With the above parameters, the output would be:

Value Analogue Units Conversion Example
Pressure Analogue Offset Value mmH2O 10 = 10mmH20
Temperature Analogue Offset Value + 1 °C * 100 1500 = 15.0°C
configure hawk

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Configure I²C Sensor Readings
  • Hawk - Configure MaxBotix MB7040 I²C Ultrasonic Range Sensor
  • Hawk - Configure T9602 Temperature Probe
  • Hawk - Configure DM Ambient (Temp+Hum Sensor)

Subscribe to Partner News

Subscribe to our mailing list to receive Digital Matter news, product and tehnical updates, and more.

Subscribe

Copyright © Digital Matter . All Rights Reserved.

Privacy Contact Support

Knowledge Base Software powered by Helpjuice

Expand