Contact Us

    If you still have questions or prefer to get help directly from an agent, please submit a request.
    We’ll get back to you as soon as possible.

    Please fill out the contact form below and we will reply as soon as possible.

    • Digital Matter Site
    • Contact Us

    Barra Recovery - Debug Logs

    Debug Log Reasons

    Written by Daan de Waard

    Updated at November 7th, 2025

      Contact Us

      If you still have questions or prefer to get help directly from an agent, please submit a request.
      We’ll get back to you as soon as possible.

      Contact Support
      • Home
      • Devices
      • Barra Recovery

      Table of Contents

      Barra Recovery General and Debug Logs On-Demand Tracking What's the Digital Input? Beacon Mode Standby & Moving Modes, Check-ins Magnet Other Log Reasons Further Debugging Information What's Next?

      Barra Recovery General and Debug Logs

      The Barra Recovery includes helpful debug logs to confirm the device actions and status:

       

      On-Demand Tracking
       

      Successful initiation of the ODT mode.

      Debug[GEN][Info]: On Demand Tracking enabled, expires 17/06/2025 06:00:00

      Successful cessation of ODT mode.

      Debug[GEN][Info]: On Demand Tracking disabled

      Incorrect initiation of ODT mode.

      Debug[GEN][Info]: On Demand Tracking expiry set in the past

      Successful expiry of ODT mode.

      Debug[GEN][Info]: On Demand Tracking expired

      Moving period initiated - When in ODT, returns selected acquisition results.

      StartofTrip[....<chosen acquisition strategy results, i.e. cell tower or WI-FI MAC IDs and Digital and Analog values>

      Locationless update while in ODT mode.

      ElapsedTime[...

      Moving period ended - When in ODT, returns selected acquisition results.

      EndofTrip[...<chosen acquisition strategy results, i.e. cell tower or WI-FI MAC IDs and Digital and Analog values>

       

      What's the Digital Input?

      If you see a digital input value in the payload, it's because within the Standby Mode system parameter tab, the below field has been enabled. This activates a digital input value for use within an end-system (i.e. Telematics Guru) to determine the current mode of operation.

      On-Demand Tracking Active Digital Input Input X
       

       

       

      Beacon Mode

      Successful initiation of beaconing.

      Debug[GEN][Sevr]: BEACON: ON exp 2942881792 (23,11796500,1000,5000)

      Successful cessation of beaconing.

      Debug[GEN][Sevr]: BEACON: off command given, turning beacon off

      Successful expiry of beaconing.

      Debug[GEN][Sevr]: BEACON: expired, turning off

      Incorrect initiation (invalid expiry).

      Debug[GEN][Sevr]: BEACON: poor expiry given, turning beacon off

       

      Standby & Moving Modes, Check-ins

      Device exits Standby Mode.

      Debug[CON][Servr]: Exiting Standby Mode

      Start-of-Moving (SoM) settings expired.

      Debug[CON][Warn]: SoM settings expired

      End-of-Moving (EoM) settings expired.

      Debug[CON][Warn]: EoM settings expired


      Start-of-Moving (SoM) check-in (configured via Digital Input).

      StartofTrip[... <cell tower ID payload if enabled> ]

      Check-in (periodic while in motion, locationless)

      CheckIn[... <cell tower ID payload if enabled> ]

      Standby Movement Digital Input (state change).

      StandbyMovementDigitalInput[... <input index / value> ]

      Trip end (returns selected acquisition results).

      EndofTrip[... <Cell ID / GNSS / Wi-Fi MACs and analog/digital values> ]

       

      Magnet

      Activation mode enabled.

      Debug[GEN][Sevr]: Activation mode enabled

      Device enters Standby Mode.

      Debug[CON][Sevr]: Entering Standby Mode

      Magnet status flag updated.

      Debug[GEN][Info]: Status flag MagnetAbsent=1, 0

      Tamper mapped to digital input (state change).

      DigitalInputChanged[... <Tamper input index / value> ]

       

      Other Log Reasons

      Trip-end with full acquisition results

      EndOfTrip[... <Cell ID / GNSS / Wi-Fi MACs and analog/digital values> ]

       

      Further Debugging Information

       

      GPL (Get Primary Location). 

      The number next to the GPL or CheckIn represents the reason for getting a location and/or checking in. For GPL:
       

      • Bit 0 = end of trip
      • Bit 1 = on demand
      • Bit 2 = on demand once
      • Bit 3 = emergency

       

      For CheckIn:

      • Bit 0 = Start of Trip
      • Bit 1 = End of Trip
      • Bit 2 = On Demand
      • Bit 3 = On Demand Once
      • Bit 4 = Check-In in Standby Mode (period elapsed) = Heartbeat.
      • Bit 5 = emergency
         

       

      What's Next?

      Read more about the Barra Recovery:

       

      • Getting Started with the Barra Recovery 
         
      • Initial Provisioning and Installation of the Barra Recovery 
         
      • Barra Recovery Modes of Operation
         
      • Barra Recovery Debug Logs 
         
         

      The following documents are withheld for security purposes. Contact your Digital Matter representative for further information. 

       

      • Barra Recovery Asynchronous Message Commands 
         
      • How to use a transceiver for last-metre device recovery
         
      • Complete downloadable user guide
         
      barra recovery recovery debug logs debug troubleshooting

      Was this article helpful?

      Yes
      No
      Give feedback about this article

      Related Articles

      • Barra Recovery - Modes of Operation