    Analog Threshold Parameters

    Written by Jake Tannenbaum

    Updated at August 7th, 2025

      Contact Us

      If you still have questions or prefer to get help directly from an agent, please submit a request.
      We’ll get back to you as soon as possible.

      Contact Support
      • Home
      • Devices
      • G70 Cellular

      Table of Contents

      Analog Threshold Parameters Example: Alert when Generator Voltage Dips Below 18V

       

      Analog Threshold Parameters

      Applicability:

      Device
      Arrow Global BLE
      Dart3 series
      G70 series

      By default, changes in analog inputs do not trigger uploads from devices. Instead, the analog value is incidentally captured whenever the device logs from other logic, like a heartbeat or trip trigger. This is not always the best method however - for example:

      • To save data/cost, scale back in trip logs + heartbeats, and force an upload if we breach a specific threshold at any time (rather than waiting for the next heartbeat)
         
      • Upload if an analog-connected fuel/tank level is dropping too quickly, and keep uploading regularly until it gets back to normal.

      To fit use cases such as these we can configure the analog threshold. 

      Example: Alert when Generator Voltage Dips Below 18V

      • We are monitoring a generator, which our device is connected to. The Dart3 or G70 external power (red and black) is wired to the generator.
         
      • The generator both powers the Dart3 or G70, but this external voltage is also what we are interested in measuring
         
      • To save data costs, and platform fees, the heartbeat has been scaled back to once daily, and in trip uploads disabled.
         
      • We want to be notified if the generator voltage dips below 18V, as this means it requires attention. 

      The image above shows settings to fit the use case. 

      Field Name Example Settings
      Analog Input Analog input 5 is the input used for external voltage
      Check Interval Sample the input every 1 min to check for changes
      Enable Low Threshold We are configuring a lower bound threshold for an alert when we dip below 18V
      Analog input 2 is the input used for Vext
      Low Threshold Value 1800 = 18V
      High and Low Hysteresis 25 means that if the voltage dips below 18V, the threshold is breached, but it has to return back to above 18.25V to reset. This stops multiple alerts going off if the asset hovers about the threshold - i.e. flicks between 17.99V and 18.01V for example. The inputs are only accurate to within approximately 100mV (0.1V) - so configure a hysteresis value above this.
      Upload on Event Start Yes = Upload as soon as we dip below 18V
      Action on Event End When we return back to 18.25V (back to threshold range) - upload again. 

       

      threshold values analog limits

      Was this article helpful?

      Yes
      No
      Give feedback about this article

      Related Articles

      • Configuring Analog Thresholds on the Falcon and Eagle

      Subscribe to Partner News

      Subscribe to our mailing list to receive Digital Matter news, product and tehnical updates, and more.

      Subscribe

      Copyright © Digital Matter . All Rights Reserved.

      Privacy Contact Support

      Knowledge Base Software powered by Helpjuice

      DM Logo
      Expand